| Form Factor |
Specialized
mid-tower workstation chassis. |
|
| Dimensions |
|
| Height |
19.3"
(49.02cm) |
| Width |
8.3"
(21.08cm) |
| Depth |
17.7"
(44.96cm) |
| Weight |
41
lbs. (19kg), Shipping Weight |
| Color |
Beige |
| |
| Hot-Swap
Drive Bays |
| Drives |
Supports
5 Ultra2 SCSI SCA2 3.5" (1.0" high) hard drives |
| SCSI
Backplane |
SCA2
connectors, thermal sensor |
| Drive
Cooling |
Two
fans attached to bays |
| |
| External
Peripheral Bays (not certified for hard drive use) |
|
2
@ 5.25 "; 1/2 height (1.6") |
| |
1
@ 3.5 "; 1/3 height (1.0") (for floppy) |
| |
| System Cooling |
| Four
fans total |
Three
92mm fans—instrumented to provide RPM data to server board for fan failure
prediction and detection |
|
One
80mm fan (in power supply) |
| |
| Security |
Chassis-intrusion
switch for alert over network (enabled by server management software which
ships with Intel's server boards) |
| |
Lockable
side cover and hot-swap drive bay |
| |
| Electrical
Power Supply |
| AC
Voltage and Frequency |
115v/60
Hz; 230v/50 Hz |
| DC
Power Supply |
300W
PFC |
| +5V |
26A
maximum continuous |
| +5V
standby |
0.8A
maximum continuous |
| +12V |
10A
maximum continuous |
| +3.3V |
16A
maximum continuous |
| -5V |
.25A
maximum continuous |
| -12V |
0.5A
maximum continuous |
| Remote
Voltage Sense |
Senses
voltage levels near server board connector for more precise power supply
voltage regulation, leading to more efficient use of power |
| |
| Front Panel |
| Power/Reset |
Power
button (momentary), system reset button, hidden NMI switch |
| LEDs |
Power,
hard drive activity, NIC activity, fan failure, 5 for hard drive failure |
| Environment |
|
| Ambient
Temperature |
|
|
Operating |
+5°
C to +35° C |
|
Non-operating |
-40°
C to 70° C ambient |
| Relative
Humidity |
|
|
Non-operating |
95%
@ 30° C non-condensing |
| Acoustics |
less
than 45 dB at typical office temperature (65-75° F) |
| Electrostatic
discharge |
20KV
per Intel Environmental test specification |
| |
| Regulations |
| The
chassis, when used with compliant motherboard, meets the following Safety
and EMC Regulations: |
| |
| Safety |
|
| U.S./Canada |
UL
1950 - CSA 950-95, 3rd Edition (UL and cUL) |
| Europe/CE
Mark |
EN60
950 2nd Edition (with Amendments 1 to 3) (CE Mark Complies with EC Directive
73/23/EEC) |
| International |
IEC
60 950 2nd Edition (with Amendments 1 to 4): CB Certificate and Report |
Norway/Sweden/
Denmark/Finland |
EMKO-TSE
(74-SEC) 207/94; Denmark, Finland NEMKO Licensed |
| Australia/New
Zealand |
AS/NZS
3260 (based on IEC 950 CB Certificate and Report) |
| |
| Electromagnetic
Compatibility (EMC) |
|
| U.S. |
FCC
CFR 47 Part 15 Class B |
| Canada |
ICES-003,
Class B |
| Europe/CE
Mark |
EN55022,
Class B & EN50082-1 (CE Mark—Complies with EC Directive 89/336/EEC) |
| International |
CISPR
22, Class B 2nd Edition |
| Japan |
VCCI,
Class B (ITE) (based on CISPR 22 Requirements) |
| Australia/New
Zealand |
AS/NZS
3548 (based on CISPR 22) |
| |